Electrical requirements for gas and steam models – IPSO T30 User Manual

Page 19

background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Tumblers – T30 and T45

18

4-08-43

Electrical Requirements for Gas and
Steam Models

Refer to Table 4 and Table 5.

NOTE: Minimum wire sizes are obtained from

Canadian Electrical Code for 75°C Conductors

and are intended for use as a guideline only.

Electrical connections should be made only by a

qualified electrical contractor in accordance with

all applicable local and national requirements.

For T30 Gas and Steam Models

(For Total Machine):

NOTE: Electrical specifications below are subject

to change without notice. Always refer to product

serial plate for most current specifications of

product being installed.

NOTE: Use copper conductors only.

NOTE: 3 Phase Only – Each tumbler must be

connected to its own individual branch circuit

breaker, not fuses, to avoid the possibility of “single

phasing” and causing premature failure of the

motor(s).

Table 4

Serial Plate Voltage

Terminal Block

Connections

Required

Current

(Amps)

Recommended

Fuse or

Breaker Rating

(Amps)

Breaker

Poles

Recommended

Minimum

Conductor Size

(AWG [mm

2

])

120V/60 Hz/1ph

L1, Neutral,

and ground

16.0

20

1

12 (3.31)

208-240V/60Hz/1ph

L1, L2, Neutral,

and ground

8.0

10

2

14 (2.08)

100V/60Hz/1ph

L1, Neutral,

and ground

22.0

30

1

10 (5.26)

200-220V/60Hz/1ph

L1, Neutral,

and ground

11.6

15

1

14 (2.08)

100V/50Hz/1ph

L1, Neutral,

and ground

24.2

35

1

8 (8.37)

200V/50Hz/1ph

L1, Neutral,

and ground

15.0

20

1

12 (3.31)

230-240V/50Hz/1ph

L1, Neutral,

and ground

15.0

20

1

12 (3.31)

200-208V/60Hz/3ph

L1, L2, L3,

and ground

6.4

10*

3

14 (2.08)

240V/60Hz/3ph

L1, L2, L3,

and ground

6.4

10*

3

14 (2.08)

200V/50Hz/3ph

L1, L2, L3,

and ground

5.8

10*

3

14 (2.08)

230-240V/50Hz/3ph

L1, L2, L3,

and ground

7.0

10*

3

14 (2.08)

380V/50 or 60Hz/3ph

L1, L2, L3,

and ground

3.0

10*

3

14 (2.08)

400-415V/50Hz/3ph

L1, L2, L3,

and ground

3.2

10*

3

14 (2.08)

460-480V/60Hz/3ph

L1, L2, L3,

and ground

3.3

10*

3

14 (2.08)

* 3 Phase machines should not have fuses, breakers only.