10 send command, Send command – FUJITSU M3097G User Manual
Page 93
4.4.10 SEND command
The following table shows the normal sequence of the SEND command when used
with this scanner.
Step
Bus phase
Initiator operation
¨ Æ
Target operation
1
BUS FREE
Verifies bus free
2
ARBITRATION
Obtains bus>usage
right
3
SELECTION
Selects target
Æ
Drives BSY signal
4
MESSAGE OUT
Selects logical unit
Æ
5
COMMAND
Specifies SEND
(CDB)
Æ
6
DATA OUT
Æ
Transfer data
7
STATUS
¨
Reports GOOD status
8
MESSAGE IN
¨
Reports Command Complete
Releases BSY signal
9
BUS FREE
(1)
SEND command: COMMAND phase (initiator Æ target)
The SEND command is used by an initiator to send data to a target. The CDB of
this command is shown in the following illustration.
Byte 0
1
2
3
4
5
6
7
8
9
Transfer identification
Operation code X©2Aπ
Logical unit number
RelAdr
(Reserved)
Transfer length
Control byte
7
6
5
4
3
2
1
0
Transfer data type
(Reserved)
(MSB)
(LSB)
(LSB)
(MSB)
4 $ 68