beautypg.com

5 send diagnostic command, Send diagnostic command – FUJITSU M3097G User Manual

Page 59

background image

l.

Sense>key specific bytes: Bytes F to 11

This field is reserved on this scanner.

(X©00000000π must not be expected.)

4.4.5

SEND DIAGNOSTIC command

The following table shows the normal sequence of the SEND DIAGNOSTIC
command when used with this scanner.

Step

Bus phase

Initiator operation

¨ Æ

Target operation

1

BUS FREE

Verifies bus free

2

ARBITRATION

Obtains bus>usage
right

3

SELECTION

Selects target

Æ

Drives BSY signal

4

MESSAGE OUT

Selects logical unit

Æ

5

COMMAND

Specifies SEND
DIAGNOSTIC
(CDB)

Æ

Performs self>test

6

STATUS

¨

Reports GOOD status

7

MESSAGE IN

¨

Reports message (Command
Complete)

Releases BSY signal

8

BUS FREE

(1)

SEND DIAGNOSTIC command: COMMAND phase (initiator Æ target)

The SEND DIAGNOSTIC command is used by an initiator to request a target or
logical unit for self>test. Two types of self>diagnostic are: (a) the self>test performed
by the unit itself, and (b) the test conducted according to the instruction data from
the initiator.

This scanner supports the self>test only.

The results of self>test are reported using the status and sense data.

The CDB of this command is shown in the following illustration.

4 $ 34