2. SYSTEM INITIALIZATION
2-2
3. Press the [
↓] key twice to choose MES Operation Mode.
4. Press the [Enter] key to open the MES operation mode options window.
Setup
9. Configuration
System Setup
01:53 02-02-25 (YY-MM-DD)
IOR
INMARSAT-C
OFF
INT
EXT
EXT
INMARSAT-C
EGC
System Date & Time
IMN
MES Operation Mode
Nav Port
Active Port
Message Output Port
EGC Output Port
Network Setup
Command Window
System setup menu, MES operation mode options window
5. Press the [
↓] or [↑] key to choose operating mode, INMARSAT-C or EGC.
The INMARSAT-C setting provides telex communications and operates as an
EGC receiver when the equipment is not transmitting or receiving. The EGC
setting enables EGC-only operation. In this case, “Current State: EGC
RECEIVER” (in reverse video) at the bottom of the screen.
6. Press the [Enter] key to close the window.
7. Press the [Esc] key to open the update window.
For technicians
Setup
9. Configuration
System Setup
System Date & Time
IMN
MES Operation Mode
Nav Port
Active Port
Message Output Port
EGC Output Port
Network Setup
Command Window
01:53 02-02-25 (YY-MM-DD)
INMARSAT-C
INT
INT
INT
INT
Update
Yes
No
8. Yes is selected; press the [Enter] key to update system settings.
9. Press the [Esc] key to return to the standby display.
Note: If the internal GPS malfunctions, enter data manually as below.
1. Choose System Date & Time from the System Setup menu and then
press the [Enter] key.
Setup
9. Configuration
System Setup
01:53 97-08 (YY-MM-DD)
INMARSAT-C
INT
INT
INT
INT
System Date & Time
IMN
MES Operation Mode
Nav Port
Active Port
Message Output Port
EGC Output Port
Network Setup
Command Window
0
2-02-25
Date and time entry window
2. Enter date with the numeric keys.
3. Press the [Enter] key to close the window.