beautypg.com

Ups solutions – 1phase – rack, Rackmount ups models, Ups options hp rack ups – 1phase – HP G1006 User Manual

Page 13

background image

13

Rackmount UPS models

Model

R/T2200 G2 Intl

R1500 G2 Intl

R3000 Intl

R5500 Intl

Part number

AF411A

AF418A

AF414A

AF416A

Form factor

Tower/Rack/2U

Rack/1U

Rack/2U

Rack/3U

Power output

2200 VA
1600 W

1500 VA
1000 W

3000 VA
2700 W

6000 VA
5400 W

Backup time at 80% load

1

8.5 mins

8 mins

6 mins

9 mins

Load segments

4

2

3

2

Output (high-voltage model)

8 x IEC320 C13 (10A)

4 x IEC320 C13

1 x IEC320 C19 (16A)
9 x IEC320 C13 (10A)

4 x IEC320 C19
4 x IEC320 C13 (10A)
1 x IEC309 (32A)

Hot-swap batteries

Yes

Yes

Yes

Yes

Weight (kg)

27.2

23

37

68

Optional ERM/part number

1/AF412A

N/A

1/AF415A

1/AF417A

Communication

USB/serial

serial (RS-232/DB9); more options available (see “UPS options”)

Communication software

includes HP Power Manager software

Warranty

3-year HP warranty (3-1-1), HP battery pre-failure warranty and integrated Care Pack Support at no additional cost

3

UPS options

HP Rack UPS – 1Phase

UPS capacity – from 1000 W to 5400 W (real power)

Patented Enhanced Battery Management (EBM) – doubles battery life up to 6 years

60-day battery – pre-failure warning and 3-year backup warranty

Extended Runtime Modules (ERMs) – increase UPS backup time by need (optional)

Load segmentation – optimises configuration flexibility and shutdown priority

Hot-swap battery modules – and electronics provide highest availability

Integrated Care Pack Support – HP Server and Storage Care Pack support of HP UPSs up to 12 kVA

at no additional cost

UPS solutions – 1Phase – Rack

Model

Description

For which HP UPS

Part number

HP UPS Management
Module

UPS management card with one ethernet port and five serial ports
(R45); embedded management software with communication and
management functions:
• Allows up to five servers to communicate direct via serial connection

and to ethernet (to servers and for remote access)

• Redundant UPS support

HP UPS R1500 G2, R3000,
HP UPS R5500 and former
HP XR models; this module
is included with R8000/3,
R12000/3 and RP36000/3

For further info, see quick specs

AF401A

4

HP Srl Adptr RJ45-DB9
DCE Female 5pk

Serial Adapters RJ45 to DB9 DCE, for the new HP Management Card
(AF401A); 5 pack

for HP UPS Management Module
(AF401A)

AF402A

1

Backup times are estimated for typical applications at recommended load level of 80%. Actual performance will depend on environment conditions,
ambient temperature, battery age and other factors. Increased system uptime possible with optional Extended Runtime Modules (ERMs).

2

Delivered incl. 4 rack PDU sticks (7 x C13 outlets each); these can be connected to the C19s on the UPS unit and provide up to
28 IEC320 C13 outputs in addition to the 4 on the unit.

3

HP Server and Storage Care Pack also supports HP UPSs up to 12 kVA at no additional cost.

4

Replaces SNMP/serial card (AF427A) and Six-port card (AF428A).

NOTE: All our products are RoHS compliant.

If you need help sizing your HP Rack and Power infrastructure solution (Rack, Rack options, UPS, PDU, KVM),
please go to www.hprackandpowersizer.com

For more UPS options, information on HP power products and software downloads, please visit
www.hp.com/products/ups