beautypg.com

Troubleshooting (cont.), Safety ser vice opera tion techniques setup – Harbor Freight Tools 95136 User Manual

Page 16

background image

Page 16

For technical questions, please call 1-800-444-3353.

SKU 95136

SAFETY

SER
VICE

OPERA

TION

TECHNIQUES

SETUP

Troubleshooting (cont.)

IMPORTANT!

Be CERTAIN to shut off the Plasma Cutter, and disconnect it from power and air before adjusting, cleaning, or

repairing the unit. A technician should discharge all capacitors before performing any internal procedures.

If the steps above do not solve the problem or if the repairs involved are too complex,

contact a qualified technician.

Take note of the

setting required for

this metal thickness.

CUT GOES ONLY PARTIALLY THROUGH THE WORKPIECE

Air pressure too low.

Check the Air Pressure setting

on the regulator’s gauge.

Turn up the current

adjustment knob

and try again.

Material being cut is too thick.

Maximum thickness for steel is 1/2″.

Cut the object along one side

and then cut along the other.

If this is not practical, use

a more powerful Cutter.

WITHIN THICKNESS

RANGE

MATERIAL

TOO THICK

a. Verify that the compressor

is delivering at least

3.5 CFM @ 80 PSI.

b. Set Regulator on the

unit to at least 60 PSI.

AIR PRESSURE

CORRECT

AIR PRESSURE

TOO LOW

PROBLEM

CORRECTED

PROBLEM PERSISTS AT

MAXIMUM SETTING

Disconnect the Torch Cables.

Disassemble the torch assembly

and inspect all internal components,

as explained on page 11.

Replace any damaged or

missing components and

reassemble carefully, following

the directions on pages 6-11.

TORCH IN GOOD

CONDITION

DAMAGED

COMPONENTS FOUND

Cut at a slower pace, the arc

may not have enough time to

cut through the workpiece.