Power specifications, Quickspecs – HP ProLiant ML330 User Manual
Page 40

460W PSU Part Number
500447-B21
Operational Input Voltage Range
(Vrms)
90 to 135
Frequency Range (Nominal) (Hz)
47 to 66 Hz
Nominal Input Voltage (Vrms)
100
115
208
220
230
240
Max Rated Output Wattage Rating
460
460
460
460
460
460
Nominal Input Current (A rms)
10
10
5
5
5
5
Max Rated Input Wattage Rating (Watts)
760
760
700
700
700
700
Max. Rated VA (Volt-Amp)
850
850
830
830
830
830
Efficiency (%)
65
65
65
65
65
65
Power Factor
0.9
0.9
0.9
0.9
0.9
0.9
Leakage Current (mA)
3.5
3.5
3.5
3.5
3.5
3.5
Maximum Inrush Current (A peak)
450
450
450
450
450
450
Maximum Inrush Current duration (mS)
HP 750W Power Supply
Part Number - AC 750W PSU
512327-B21
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal)
(Hz)
50/60
Nominal Input Voltage (Vrms)
100
120
200
208
220
230
240
Maximum Rated Output Wattage
750
750
750
750
750
750
750
Nominal Input Current (A rms)
8.9
7.4
4.3
4.1
3.9
3.7
3.6
Max Rated Input Wattage Rating
(Watts)
857
847
824
825
820
820
820
Max. Rated VA (Volt-Amp)
894
884
859
859
854
854
854
Efficiency (%) at Max. Rated
Output Wattage
87.5
88.5
91
91
91.5
91.5
91.5
Power Factor
0.97
0.97
0.97
0.97
0.97
0.97
0.97
Leakage Current (mA)
0.42
0.50
0.83
0.87
0.92
0.96
1.00
Max. Inrush Current (A peak)
30
30
30
30
30
30
30
Max. Inrush Current duration
(mS)
20
20
20
20
20
20
20
Maximum British Thermal Unit
Rating (BTU-Hr)
2925
2892
2812
2812
2797
2797
2797
NOTE: It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power supply for your need.
The HP Power Advisor is located at:
QuickSpecs
HP ProLiant ML330 Generation 6
Power Specifications
DA - 13361 Worldwide QuickSpecs — Version 17 — 3-31-2010
Page 40