beautypg.com

2. typical mig process control settings – Hobart Welding Products HANDLER 140 OM-925 User Manual

Page 37

background image

OM-925 Page 33

9-2.

Typical MIG Process Control Settings

.

These settings are guidelines only. Material and wire type, joint design, fitup, position, shielding gas, etc. affect settings. Test welds to be sure
they comply to specifications.

3.5 x 125 A = 437 ipm

2 x 125 A = 250 ipm

1.6 x 125 A = 200 ipm

30 − 90 A

40 − 145 A
50 − 180 A

Convert Material

Thickness to

Amperage (A)

Material thickness determines weld

parameters.

.035 in

Recommendation

Wire Speed

(Approx.)

1/8 or 0.125 in

(0.001 in = 1 ampere)

0.125 in = 125 A

Wire Size

Amperage Range

0.023 in
0.030 in
0.035 in

Select Wire Size

Wire

Size

0.023 in
0.030 in
0.035 in

3.5 in per ampere

2 in per ampere

1.6 in per ampere

Select Wire Speed

(Amperage)

125 A based on 1/8 in

material thickness

ipm = inches per minute

Low voltage: wire stubs into work

High voltage: arc is unstable (spatter)

Set voltage midway between high/low voltage

Select Voltage

Ref. 803 710-C

Voltage controls height and

width of weld bead.

Wire speed (amperage) controls weld

penetration (wire speed = burn-off rate)

This manual is related to the following products: