Table a-18 scsi interface error messages – HP DC5850 User Manual
Page 110
A-18
www.hp.com
Technical Reference Guide
Error Messages and Codes
A.19 SCSI Interface Error Messages (65xx-xx, 66xx-xx,
67xx-xx)
n = 5, Hard drive
= 6, CD-ROM drive
= 7, Tape drive
yy = 00, ID
= 03, Power check
= 05, Read
= 06, SA/Media
= 08, Controller
= 23, Random read
= 28, Media load/unload
Table A-18
SCSI Interface Error Messages
Message
Probable Cause
Message
Probable Cause
6nyy-02
Drive not installed
6nyy-33
Illegal controller command
6nyy-03
Media not installed
6nyy-34
Invalid SCSI bus phase
6nyy-05
Seek failure
6nyy-35
Invalid SCSI bus phase
6nyy-06
Drive timed out
6nyy-36
Invalid SCSI bus phase
6nyy-07
Drive busy
6nyy-39
Error status from drive
6nyy-08
Drive already reserved
6nyy-40
Drive timed out
6nyy-09
Reserved
6nyy-41
SSI bus stayed busy
6nyy-10
Reserved
6nyy-42
ACK/REQ lines bad
6nyy-11
Media soft error
6nyy-43
ACK did not deassert
6nyy-12
Drive not ready
6nyy-44
Parity error
6nyy-13
Media error
6nyy-50
Data pins bad
6nyy-14
Drive hardware error
6nyy-51
Data line 7 bad
6nyy-15
Illegal drive command
6nyy-52
MSG, C/D, or I/O lines bad
6nyy-16
Media was changed
6nyy-53
BSY never went busy
6nyy-17
Tape write-protected
6nyy-54
BSY stayed busy
6nyy-18
No data detected
6nyy-60
Controller CONFIG-1 register fault
6nyy-21
Drive command aborted
6nyy-61
Controller CONFIG-2 register fault
6nyy-24
Media hard error
6nyy-65
Media not unloaded
6nyy-25
Reserved
6nyy-90
Fan failure
6nyy-30
Controller timed out
6nyy-91
Over temperature condition
6nyy-31
Unrecoverable error
6nyy-92
Side panel not installed
6nyy-32
Controller/drive not connected
6nyy-99
Autoloader reported tape not loaded properly