Quickspecs – HP DC5800 User Manual
Page 41

The EPE foam packaging material is made from 30 to 60% industrial recycled content.
The corrugated paper packaging materials contain at least 80% post consumer recycled
content.
Minitower
System Configuration The configuration used for the Energy Consumption and Declared Noise Emissions data for the
Minitower Desktop model is based on a typically configured product.
Energy Consumption
AC Input Voltage at 115 VAC
+/- 5 VAC, 60 Hz +/- 3 Hz
AC Input Voltage at 230 VAC
+/- 5 VAC, 50 Hz +/- 3 Hz
AC Input Voltage at 100 VAC
+/- 5 VAC, 50 Hz +/- 3 Hz
Normal Operation On-
Idle (ENERGY STAR
Idle (S0))
57.7234 W
57.1631 W
58.1231 W
ENERGY STAR “Sleep”
(S3) (Wake On LAN
(WOL) Enabled)
3.0145 W
3.3215 W
2.9863 W
ENERGY STAR “Sleep”
(S3) (Wake On LAN
(WOL) Disabled)
3.0142 W
3.3181 W
2.983 W
ENERGY STAR
“Standby” (Off) (S5)
(Wake On LAN (WOL)
Enabled)
1.4702 W
1.7589 W
1.4495 W
ENERGY STAR
“Standby” (Off) (S5)
(Wake On LAN (WOL)
Disabled)
0.8089 W
1.0882 W
0.7862 W
Heat Dissipation*
AC Input Voltage at 115 VAC
+/- 5 VAC, 60 Hz +/- 3 Hz
AC Input Voltage at 230 VAC
+/- 5 VAC, 50 Hz +/- 3 Hz
AC Input Voltage at 100 VAC
+/- 5 VAC, 50 Hz +/- 3 Hz
Normal Operation On-
Idle (ENERGY STAR
Idle (S0))
196.952 BTU/hr
195.04 BTU/hr
198.316 BTU/hr
ENERGY STAR “Sleep”
(S3) (Wake On LAN
(WOL) Enabled)
10.285 BTU/hr
11.332 BTU/hr
10.189 BTU/hr
ENERGY STAR “Sleep”
(S3) (Wake On LAN
(WOL) Disabled)
10.284 BTU/hr
11.321 BTU/hr
10.177 BTU/hr
ENERGY STAR
“Standby” (Off) (S5)
(Wake On LAN (WOL)
Enabled)
5.016 BTU/hr
6.001 BTU/hr
4.945 BTU/hr
ENERGY STAR
“Standby” (Off) (S5)
(Wake On LAN (WOL)
Disabled)
2.759 BTU/hr
3.712 BTU/hr
2.682 BTU/hr
* Heat dissipation is calculated based on the measured watts, assuming the service level is attained for one hour.
This product is in compliance with US executive order 13221, WOL (wake on LAN) disabled.
QuickSpecs
HP Compaq dc5800 Business PC
Technical Specifications - Environmental Data
DA - 12863 U.S. QuickSpecs — Version 3 — 4/2/2008