beautypg.com

Power specifications, Quickspecs – HP PROLIANT ML350 G6 User Manual

Page 49

background image

HP 460W CS HE Power Supply Kit
Part Number

503296-B21

Input Voltage Range (Vrms)

100 to 240

Frequency Range (Nominal)
(Hz)

50/60

Nominal Input Voltage (Vrms)

100

120

200

208

220

230

240

Maximum Rated Output
Wattage Rating

460

460

460

460

460

460

460

Nominal Input Current (A rms)

5.5

4.5

2.6

2.5

2.4

2.3

2.2

Maximum Rated Input Wattage
Rating (Watts)

526

520

505

505

503

503

503

Maximum Rated VA (Volt-Amp)

548

542

527

527

524

524

524

Efficiency (%)

87.5

88.5

91

91

91.5

91.5

91.5

Power Factor

0.97

Leakage Current (mA)

0.42

0.50

0.83

0.87

0.92

0.96

1.00

Maximum Inrush Current (A
peak)

30

Maximum Inrush Current
duration (mS)

20

Maximum British Thermal Unit
Rating (BTU-Hr)

1794

1773

1725

1725

1715

1715

1715

HP 750W CS HE Power Supply Kit
Part Number

512327-B21

Input Voltage Range (Vrms)

100 to 240

Frequency Range (Nominal)
(Hz)

50/60

Nominal Input Voltage (Vrms)

100

120

200

208

220

230

240

Maximum Rated Output
Wattage Rating

750

750

750

750

750

750

750

Nominal Input Current (A rms)

8.9

7.4

4.3

4.1

3.9

3.7

3.6

Maximum Rated Input Wattage
Rating (Watts)

857

847

824

825

820

820

820

Maximum Rated VA (Volt-Amp)

894

884

859

859

854

854

854

Efficiency (%)

87.5

88.5

91

91

91.5

91.5

91.5

Power Factor

0.97

Leakage Current (mA)

0.42

0.50

0.83

0.87

0.92

0.96

1.00

Maximum Inrush Current (A
peak)

30

Maximum Inrush Current
duration (mS)

20

Maximum British Thermal Unit
Rating (BTU-Hr)

2925

2892

2812

2812

2797

2797

2797

QuickSpecs

HP ProLiant ML350 Generation 6

Power Specifications

DA - 13241 Worldwide QuickSpecs — Version 38 — 3/16/2011

Page 49