beautypg.com

Technical specifications, Quickspecs – HP Integrity server blade BL860c User Manual

Page 30

background image

System Unit

Dimensions

Height

14.42 in (36.63 cm)

Depth

20.02 in (50.85 cm)

Width

2.03 in (5.16 cm)

Shipping Dimensions

Height

21.50 in (54.61 cm)

Depth

23.13 in (58.75 cm)

Width

9.94 in (25.25 cm)

Weight

Maximum

22.8 lbs (10.3 kg)

Temperature Range

*

Operating

10° to 35° C (50° to 95° F)

Non-Operating

-40° to 60° C (-40° to 140° F)

Storage

-20° to 60° C (-4° to 140° F)

Maximum Wet Bulb
Temperature

30° C (86° F)

Relative Humidity

**

Operating

10% to 90%

Shipping

10% to 90%

Storage

10% to 95%

* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F
per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Upper operating limit
is 3,048m (10,000 ft) or 70 Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3
KPa/4.4 psia.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F).
Altitude maximum for storage corresponds to a pressure minimum of 70 KPa.

SAS RAID LSI 1068
Controller

Disk Drive and
Enclosure Interface

3G SAS (Serial Attached SCSI)

SAS Connectors

2 internal (SFF8484) x4 wide port connectors

Cache Memory Speed DDR-1/266 MHz provides up to 4.2 GB/s maximum bandwidth.

Server Interface

x8 2.5G PCIe provides 2GB/s maximum bandwidth.

SAS Speed

x8 3G SAS provides 2.4GB/s maximum bandwidth.

Cache Memory

40-bit 64MB or 128MB cache: ECC protection, battery-backed, and
transportable

Logical Drives
Supported

Up to 32 logical volumes

Maximum Logical Drive
Capacity

292GB (2 x 146GB)

Host Memory
Addressing

64-bit, supporting greater than 4GB server memory space

RAID Support

RAID 1 (Mirroring)

Upgradeable Firmware Upgradeable Firmware

QuickSpecs

HP Integrity BL860c Server Blade

Technical Specifications

DA - 12671 U.S. QuickSpecs — Version 18 — 2/18/2009

Page 30