E. Junction Box Installation

If the box is being wired from the OUTSIDE of the appli-
ance:

• Remove the cover plate located on the outer shell - right

side (see Figure 12.2).

• Install the supplied Romex™ connector in the cover

plate.

• Feed the necessary length of wire through the

connector.

• Make all necessary wire connections and reattach the

cover plate to the outer shell.

If the box is being wired from the INSIDE of the appli-
ance:

• Remove the screw attaching the junction box/receptacle

to the outer shell, rotate the junction box inward to
disengage it from the outer shell (see Figure 12.2).

• Pull the electrical wires from outside the appliance

through this opening into the valve compartment.

• Feed the necessary length of wire through the

connector.

• Make all necessary wire connections to the junction box/

receptacle and reassemble the junction box/receptacle
to the outer shell.

WHT

W

HT

BLK

BLK

GRN wire
inside box

Copper
ground attached
to GRN screw with
GRN wire

14/2WG

Cover Plate
outside firebox

Romex
Connector

Figure 12.2 Junction Box Detail

Note: Do NOT wire 110

VAC to wall switch.

Red

Switch

Switch Box

Red

Black

Black

Green

Green

White

Power

Supply

Wires

White

Red

Black

Green

White

Minimum 14-3 AWG
with Ground

Junction Box

Knockout

Figure 12.3 Junction Box Wired to Wall Switch or BC10

F. Wall Switch Installation for Fan (Optional)

If the box is being wired to a wall mounted switch for use
with a fan, see Figure 12.3:

• The power supply for the appliance must be brought into

a switch box.

• The power can then be supplied from the switch box

to the appliance using a minimum of 14-3 with ground
wire.

• At the switch box connect the black (hot) wire and red

(switch leg) wire to the wall switch as shown.

• At the appliance connect the black (hot), white (neutral)

and green (ground) wires to the junction box as
shown.

• Add a 1/4 in. insulated female connector to the red

(switch leg) wire, route it through the knockout in the face
of the junction box, and connect to the top fan switch
connector (1/4 in. male) as shown.