beautypg.com

D. mantel and wall projections, Mantels mantel legs or wall projections – Hearth and Home Technologies Heatilator GDST5244I User Manual

Page 19

background image

Heatilator • GDST5244I • 4045-127 • Rev W • 11/08

19

Measured from top of fireplace opening (in inches)

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

4-5/8

6-1/4

7

7-3/4

8-1/2

9-1/4

10

10-3/4

11-1/2

12-1/4

13

13-3/4

14-1/2

15-1/4

16

16-3/4

30 in. minimum

to ceiling

D. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).

Figure 5.3 Minimum Vertical and Maximum Horizontal
Dimensions

0 in. min.
to perpendicular wall

A

4-5/8 in. (117 mm) min.
from fireplace opening
to perpendicular wall

B

Mantel Leg or

Perpendicular Wall

Top of
Appliance

Drywall

A

B

Figure 5.4 Mantel Leg or Wall Projections (Acceptable on both
sides of opening)

Mantels

Mantel Legs or Wall Projections