beautypg.com

Water-cooled condenser, A) connection to an open drain system – Hoshizaki KMH-2000SWH/3 User Manual

Page 26

background image

26

2. Water-Cooled Condenser

a) Connection to an Open Drain System
• Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" nominal

copper water tubing is recommended for the condenser water supply line.

• A condenser water supply line shut-off valve and drain valve should be installed.
• Condenser drain outlet is 3/8" FPT. A minimum of 3/8" nominal hard pipe is recommended

for the condenser drain line.

• In some areas, a back flow preventer may be required in the cooling water circuit.
• In order to maintain the proper high side pressure, the condenser water supply inlet

temperature should not drop below 45°F (7°C) and the condenser drain outlet temperature
must be in the 104°F to 115°F (40°C to 46°C) range. Once the icemaker installation
is complete, confirm the condenser drain outlet temperature 5 minutes after a freeze
cycle starts. If the condenser drain outlet temperature is not in the proper range, use a
flat blade screwdriver to rotate the adjustment screw on the water-regulating valve until
the temperature is in the proper range (rotate counterclockwise to raise temperature or
clockwise to lower temperature).

Fig. 17

KMH-2000SWH/3

Connection to an Open Drain System

Separate piping to approved drain.

Leave a 2-inch (5-cm) vertical air

gap between the end of each pipe

and the drain.

Icemaker Water Supply Line

Shut-Off Valve

Icemaker Water Supply Line

Drain Valve

Icemaker

Icemaker

Water Supply

Inlet

1/2" FPT

Bin Drain Outlet

See Manufacturer's Instructions

2-inch (5-cm) air gap

Floor Drain

Icemaker

Drain Outlet

3/4" FPT

Bin

Condenser Water Supply Line

Shut-Off Valve

Condenser Water Supply Line

Drain Valve

Condenser Water

Supply Inlet

1/2" FPT

Condenser

Drain Outlet

3/8" FPT

Vent Tube

Vent Tube

Minimum 1/2" Nominal Copper Water Tubing

Minimum 3/4" Nominal Hard Pipe

Minimum 3/8"

Nominal Hard

Pipe

Condensation

Drain Outlet

3/8" OD Hard Tube

Vent Tube

Minimum 3/8" Nominal Copper Water Tubing