Fig. 6 – Hoshizaki KMH-2000SWH/3 User Manual
Page 15
15
7) Install the bin control thermostat as follows:
a. Remove the thermostat bulb attachment (plastic) of the upper unit from the
thermostat extension bracket (stainless). See Fig. 6.
b. Carefully remove the thermostat bulb from the thermostat bulb attachment (plastic)
of the upper unit, then remove the silicone hose from the capillary tube.
c. Carefully route the thermostat bulb and capillary tubing of the upper unit through
the bottom hole of the upper unit. Remove the bushing from the lower bin control
thermostat assembly. Route the bulb and tubing through the hole in the assembly
and down into the bin. Reattach the bushing.
d. Secure the lower bin control thermostat assembly in place with the thumbscrews.
e. Slide the silicone hose onto the capillary tube, then carefully insert the thermostat
bulb back into the thermostat bulb attachment (plastic).
f. Secure the thermostat bulb attachment (plastic) of the upper unit to the thermostat
bulb attachment (plastic) of the lower unit with the screws of the upper unit.
g. Make sure the silicone hose is in place to prevent ice from striking the capillary tube.
h. Insert the plug of the upper unit into the receptacle of the upper unit's bin control
thermostat assembly until it locks into place.
Note: Icemaker will not run if the plug is not in the receptacle.
8) Replace the panels and baffle in their correct positions.
Thermostat
Capillary
Tubing
Fig. 6
Thermostat Extension
Bracket (stainless)
Thermostat Bulb
Attachment
Removed from
Upper Unit
Thermostat Bulb
Attachment of
Lower Unit
Thermostat Bulb
"Z" Bracket
(plastic)
Silicone Hose