beautypg.com

F. electrical connection, Warning, F. electrical connection warning – Hoshizaki KMH-2000SWH/3 User Manual

Page 16

background image

16

F. Electrical Connection

WARNING

For All Models

1. Electrical connection must be hard-wired and must meet national, state, and

local electrical code requirements. Failure to meet these code requirements
could result in death, electric shock, serious injury, fire, or extensive damage
to equipment.

2. This unit requires an independent power supply. See the nameplate for

proper voltage and breaker/fuse size. Failure to use a proper breaker or fuse
can result in a tripped breaker, blown fuses, or damage to existing wiring.
This could lead to heat generation or fire.

3.

THIS UNIT MUST BE GROUNDED. Failure to properly ground this unit

could result in death or serious injury.

4. Electrical connection must be made in accordance with the instructions on

the "WARNING" tag, provided with the pig tail leads in the junction box. See
Fig. 7a and 7b.

Additional Warnings for Remote Air-Cooled Model

5.

THE REMOTE CONDENSER UNIT MUST BE GROUNDED. The power

supply and ground wire to the remote condenser unit are supplied from the
icemaker. See "II.G.6. Electrical Connection."

6. To reduce the risk of electric shock, make all remote condenser unit

connections before connecting the icemaker power supply.

7. On remote air-cooled model, the icemaker should have power for a minimum

of 4 hours prior to startup to prevent compressor damage.

• Usually an electrical permit and services of a licensed electrician are required.
• The maximum allowable voltage variation is ±10 percent of the nameplate rating.
• On single phase models, the white lead must be connected to the neutral conductor of the

power source.

CAUTION! Miswiring may result in severe damage to the icemaker.

KMH-2000SWH

KMH-2000SRH

Fig. 7a

 WARNING

ELECTRICAL CONNECTION

THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage
to the icemaker. The white lead
must be connected to the neutral
conductor of the power source.
See diagram below.

4A4801-010

208-230/60/1

(3 wire with neutral for 115V)

JUNCTION BOX

208-230

V

BROWN

BLACK

L1

L2

WHITE

N

115- 120V

This manual is related to the following products: