beautypg.com

Caution – Heat & Glo Fireplace CRESCENT II User Manual

Page 28

background image

Heat & Glo • Crescent II • 2083-902 Rev. L • 7/08

28

Figure 10.1 Intelli

fi re Pilot Ignition (IPI) W

iring Diagram - Standard Method Note:

Appliance will not operate unless properly grounded.

CAUTION

Wire terminal latch can become

damaged if excessive force is

used when releasing wire. Please

use caution in pressing retainer

.

IGNITION

MODULE

3 V

A

C

INTERMITTENT

PILOT IGNIT

O

R

VA
LV
E

ORG

WHT

ORG

GRN

SWITCH

BACK OF

SWITCH

CIRCUIT BOARD

12VDC

LIGHT SOCKETS

SOLENOID (NG ONL

Y

)

J-BOX

BLACK

GREEN

RED

YELLOW

WHITE

BLACK

BROWN

BROWN

MADE INMADE IN

CANADACANADA

50-025302-D

50-025302-D

++

P2P2

HIHI

12V12V

COMCOM

C1C1

C2C2

R1R1

P1P1

REMREM

REMREM

D1D1

J1J1

D2D2

C2C2

K3K3

K2K2

R4R4

K1K1

R1R1

D3D3

C1C1

PRESS. SWPRESS. SW

T16T16

T15T15

LINE NEU

SOLENOID

T14

T13

T12

T11

T10

T9

1

C

3

2

EMBER LIGHTS

HI/LOW

T14

T13

T12

T11

T10

T9

1

C

OFF/ON

3

2

EMBER

T6

T5

T6

T5

IPI

T2

T1

T2

T1

TRANSFORMER

3 V

A

C

PLUG IN

J-BOX

BLACK WIRE CAN

BE PLUGGED INT

O

ANY

OF #1 - #5

LOCA

TIONS

ON THE HOT SIDE

WHITE WIRE CAN BE

PLUGGED INT

O

ANY

OF #1 - #5 LOCA

TIONS

ON THE NEUTRAL

SIDE

PLUG

IN

J-BOX

GROUND

T

O

FIREPLACE

CHASSIS