beautypg.com

Quickspecs – HP PROLIANT DL180 User Manual

Page 51

background image

(non-condensing)

(82.4°F) maximum wet bulb temperature, non-
condensing.

Non-operating

5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature,
non-condensing.

Altitude

Operating

3050 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
457 m/min (1500 ft/min).

Non-operating

9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).

Acoustic Noise

Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA
74) and declared in accordance with ISO 9296 (ECMA 109).

Idle

LWAd

5.3 B

LpAm

38 dBA

Operating

LWAd

5.3 B

LpAm

38 dBA

NC362i Integrated Dual
Port Gigabit Server
Adapter

Network Interface

Integrated 10/100/1000BASE-T Transceiver

Combines a triple-speed IEEE 802.3TM - Compliant Media Access
Controller (MAC) with a triple-speed Ethernet transceiver.

Data Transfer Method

Compliant to x1 PCIe Specification

Controller

Intel® 82576

Network Transfer Rate 10Base-T (Half-Duplex)

10 Mb/s

10Base-T (Full-Duplex)

20 Mb/s

100Base-TX (Half-
Duplex)

100 Mb/s

100Base-TX (Full-
Duplex)

200 Mb/s

1000Base-TX (Half and
Full-Duplex)

2000 Mb/s

Connector

RJ-45

Cable Support

Performs all the physical layer functions for 10BASE-T, 100BASE-T,
and 1000BASE-T Ethernet on standard Category 5 UT

QuickSpecs

HP ProLiant DL180 Generation 6

Technical Specifications

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010

Page 51