The P43 Pellet Stove is capable of manual operation. This also allows the operator

to manually control operation during an emergency (i.e. igniter failure, when using a

50H battery backup, as opposed to the 51H, or when using certain generators.)

The unit can be switched between "AUTO" and "MANUAL" at any time during op-

eration.

igniter Switch to "Manual"

room temperature Mode

The fire will have to be lit with starting gel and a

match, or started automatically, see "Automatic Opera-

tion" on Page 15. Turn to "Manual" position when the

fire is established.

The difference between "AUTO" Room Temperature

Mode and "Manual" Room Temperature Mode is that

the fire will not go out as the room temperature goes

above the control board setting. The unit can only go to

low burn and will remain there until it runs out of fuel or

until more heat is needed and the feed rate increases.

Feed rate adjustments and dial settings are the same

as "AUTO" settings.

The blower will shut off com-

pletely if the temperature on the ESP is too low.

igniter Switch to "Manual"

Stove temperature Mode

The advantage of this mode is to allow the operator

to have a large viewing fire without blowing extra heat

into the room.

During operation, with the temperature dial set at

#5 or less, the distribution fan will not operate. A #5 on

the temperature dial and a #5 on the feed adjuster is

approximately 80% output. It is not necessary to oper-

ate the distribution blower below this point. This control

setting allows a higher burn rate (a larger viewing fire)

without an excess of hot air blowing into the room.

An example of when to use the Manual Stove Tem-

perature Mode is if you want to watch a large fire and

the room is already up to temperature. The Stove

Temperature Mode allows you to have a larger fire and

a lower sound level, without the distribution blower.

nOte: during the use of this mode, if you keep

increasing the temperature dial setting to increase

the fire size, the distribution blower will automati-

cally come on when the eSP temperature reaches

350

o

F, or 81% output.

nOte: when starting the unit in the "autO"

mode and switching to "MANUAL", the fire must be

large enough to start the distribution blower. the

starting of the blower is a signal that the start cycle

is completed and the fire will not go out.

P43 Manual ignitiOn/OPeratiOn

This setting will produce a large viewing fire

without a distribution blower operating.

Manual Stove temperature Mode

Room Temperature Mode: This

setting, see below, will produce a

room temperature of 70 degrees

with the distribution blower at

medium speed.