Sanitizing solution, Important, Fig. 4 – Hoshizaki F-300BAF User Manual
Page 46
46
8) Remove the thumbscrews attaching spout
(A) to the evaporator assembly and lift off
spout (A) and spout packing (A). See Fig 4.
9) Pour the cleaning solution over the
extruding head until the evaporator
assembly and the reservoir are filled and
the solution starts to overflow into the drain
pan.
Note: If there is excess scale on the extruding head, fill the evaporator assembly and
reservoir as described above, then use a clamp on the reservoir hose between
the reservoir and evaporator assembly to block flow. Pour additional cleaning fluid
over the extruding head until the evaporator assembly is completely full.
10) Using the thumbscrews, replace spouts (A) and (B) and spout packings (A) and (B) in
their correct positions.
11) Allow the icemaker to sit for about 10 minutes before operation. If you placed a clamp
on the reservoir hose in step 9, remove it before operation.
12) Move the flush switch to the "ICE" position, then turn on the power supply. Replace the
top panel and the front panel in their correct positions. Make ice using the solution until
the icemaker stops making ice.
13) Remove the front panel.
14) Move the flush switch to the "FLUSH" position to drain the remainder of the solution.
15) After the solution is drained, move the flush switch to the "ICE" position.
16) Replace the front panel in its correct position.
17) Open the water supply line shut-off valve, and supply water to the reservoir.
18) When the gear motor starts, remove the top panel and front panel. Turn off the power
supply.
19) Drain out all water from the water line. See 4) through 6).
3. Sanitizing Solution
Dilute 2.5 fl. oz. (74 ml or 5 tbs) of a 5.25% sodium hypochlorite solution (chlorine
bleach) with 5 gallons (19 l) of warm water.
IMPORTANT
For safety and maximum effectiveness, use the solution immediately after
dilution.
Thumbscrews
Spout (A)
Evaporator Assembly
Fig. 4
Spout (A) Packing