beautypg.com

B. diagnostic charts, No ice production – Hoshizaki F-300BAF User Manual

Page 29

background image

29

B. Diagnostic Charts

1. No Ice Production

Problem

Possible Cause

Remedy

[1] The icemaker will not

start. (fill cycle, water
valve)

a) Power Supply

1. Off.

1. Turn on.

2. Power cord

unplugged.

2. Plug into receptacle.

3. Loose connection.

3. Tighten.

4. Bad contacts.

4. Check for contintinuity and

replace.

5. Blown fuse.

5. Replace.

b) Power Switch

(Control Box)

1. OFF position.

1. Move to ON position.

2. Bad contacts.

2. Check for continuity and

replace.

c) High Pressure Switch

1. Dirty air filter or

condenser.

1. Clean.

2. Ambient or condenser

water temperature too
warm.

2. Reduce temperature.

3. Condenser water

pressure too low or off.
(water-cooled model
only)

3. Check and get

recommended pressure.

4. Water regulating valve

set too high. (water-
cooled model only)

4. Adjust it lower.

5. Fan not rotating.

5. See "3. [1] a) Fan Motor.”

6. Refrigerant

overcharged.

6. Recharge.

7. Refrigerant line or

components plugged.

7. Clean and replace drier.

8. Bad contacts.

8. Check for continuity and

replace.

9. Loose connections.

9. Tighten.

d) Transformer

1. Coil winding opened.

1. Replace.

e) Spout Safety Switch

and Relay

1. Bin control not

activating.

1. Check bin control actuator

and proximity switch.

f) Fuse (Control Box)

1. Blown.

1. Check for short circuit and

replace.

g) Bin Control

1. Actuator sticking.

1. Adjust or replace.

2. Proximity switch open. 2. Replace.

h) Flush Switch

1. FLUSH position.

1. Move to ICE position.

2. Bad contacts.

2. Check for continuity and

replace.

i) Flush Switch Relay

1. Coil open.

1. Replace.