3. Other

Problem

Possible Cause

Remedy

[1] Abnormal noise

a)Fan Motor

1. Bearing worn out.

1. Replace.

2. Fan blade deformed.

2. Replace fan blade.

3. Fan blade does not

move freely.

3. Replace.

b)Compressor

1. Bearings worn out, or

cylinder valve broken.

1. Replace.

2. Mounting pad out of

position.

2. Reinstall.

c) Refrigerant Lines

1. Rub or touch lines or

other surfaces.

1. Replace or separate.

d)Gear Motor

1. Bearing or gear worn

out / damaged.

1. Replace.

e)Evaporator

1. Low refrigerant

pressures.

1. Check charge, check for

possible leak, repair,
re-charge.

2. Expansion valve bad. 2. Replace.
3. Evaporator bad.

3. Replace.

4. Scale on inside wall of

freezing cylinder.

4. Use "SCALE AWAY" to

clean periodically. If the
water is found hard by
testing, install a softener.

[2] Overflow from

reservoir (water does
not stop).

a)Water Supply

1. Water pressure too

high.

1. Install a pressure reducing

valve.

b)Water Valve

1. Diaphragm does not

close.

1. Clean or replace.

c) Float Switch

1. Bad contacts.

1. Check for continuity and

replace.

d)Water Control Relay

1. Bad contacts.

1. Replace

[3] Gear motor protector

operates frequently or
fuse blows frequently.

a)Power Supply Voltage

1. Too high or too low.

1. Connect the unit to a

power supply of proper
voltage.

b)Evaporator Assembly

1. Bearings or auger

worn out.

1. Replace bearings or

auger.

c) Bin Control

1. Bad contacts.

1. Check for continuity and

replace.

2. Actuator does not

move freely.

2. Clean shaft and its

corresponding holes or
replace bin control.