Problem

Possible Cause

Remedy

e) Compressor

1. Loose connections.

1. Tighten.

2. Motor winding opened

or grounded.

2. Replace.

3. Compressor locked

and motor protector
tripped.

3. Replace compressor.

f) Power Supply

1. Circuit ampacity too

low.

1. Install a larger-sized

circuit.

[5] Gear motor and

compressor start, but
no ice is produced.

a) Refrigerant Line

1. Gas leaks.

1. Check for leaks with a

leak detector. Replace
drier and charge with
refrigerant. Refrigerant
charge is marked on
nameplate or rating label.

2. Refrigerant line

clogged.

2. Replace the clogged

component.

2. Low Ice Production

Problem

Possible Cause

Remedy

[1] Low ice production.

a)Refrigerant Line

1. Gas leaks.

1. See "2. [5] a) Refrigerant

Line."

2. Refrigerant line

clogged.

2. Replace the clogged

component.

3. Overcharged.

3. Recharge.

b)High-Side Pressure Too

High

1. Dirty air filter or

condenser.

1. Clean.

2. Ambient or condenser

water temperature too
warm.

2. Reduce temperature.

3. Condenser water

pressure too low or off.
[water-cooled model
only]

3. Check and get recom-

mended pressure.

4. Fan, slow rpm.

4. See "3. [1] a) Fan Motor".

5. Water regulating valve

clogged. [water-cooled
model only]

5. Clean.

c) Expansion Valve (not

adjustable)

1. Low-side pressure too

low.

1. Replace.

2. Low-side pressure too

high.

2. See if expansion valve

bulb is mounted properly,
and replace the valve if
necessary.