D. performance data – Hoshizaki F-300BAF User Manual
Page 26

26
D. Performance Data
1. F-300BAF
APPROXIMATE
Ambient
Water Temp. (°F)
ICE PRODUCTION
Temp. (°F)
PER 24 HR.
70
*303 *(137)
290
(131)
278
(126)
80
267
(121)
256
(116)
246
(112)
90
236
(107)
*232 *(105)
218
(99)
lbs./day (kg/day)
100
209
(95)
201
(91)
*188
*(85)
APPROXIMATE ELECTRIC
70
*667
--
668
--
669
--
CONSUMPTION
80
670
--
671
--
672
--
90
673
--
*674
--
681
--
watts
100
688
--
695
--
*702
--
APPROXIMATE WATER
70
*36
*(137)
35
(131)
33
(126)
CONSUMPTION PER 24 HR.
80
32
(121)
31
(116)
30
(112)
90
28
(107)
*28
*(105)
26
(99)
gal./day (l/day)
100
25
(95)
24
(91)
*23
*(85)
EVAPORATOR OUTLET TEMP.
70
*19
*(-7)
19
(-7)
19
(-7)
80
19
(-7)
22
(-6)
22
(-6)
90
22
(-6)
*22
*(-6)
26
(-4)
°F (°C)
100
26
(-4)
26
(-4)
*26
*(-4)
HEAD PRESSURE
70
*250 *(17.5)
250
(17.5)
250
(17.5)
80
280
(19.7)
280
(19.7)
280
(19.7)
90
311
(21.9)
*311 *(21.9)
311
(21.9)
PSIG (kg/cm²G)
100
351
(24.7)
351
(24.7)
*351 *(24.7)
SUCTION PRESSURE
70
*35
*(2.5)
35
(2.5)
35
(2.5)
80
37
(2.6)
37
(2.6)
37
(2.6)
90
39
(2.7)
*39
*(2.7)
39
(2.7)
PSIG ( kg/cm²G )
100
43
(3.0)
43
(3.0)
*43
*(3.0)
TOTAL HEAT OF REJECTION
3178 BTU/h (AT 90°F /WT 70°F)
Note: The data without *marks should be used for reference.
50
70
90
We reserve the right to make changes to specifications and design without prior notice.