Before operating this fi replace for the fi rst time,

have a

qualifi ed technician:
• Verify all shipping materials have been removed from

inside and/or underneath the fi rebox.

• Review proper placement of logs, ember material and/

or other decorative materials.

• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Ensure that the glass is sealed and in the proper position

and that the integral barrier is in place.

WARNING! Risk of Fire/Asphyxiation! DO NOT oper-

ate fi replace with fi xed glass assembly removed.
Determine if this fi replace has a standing pilot or an

Intellifi re ignition system. Ask your dealer or open control

access panel, look at gas valve.
• A standing pilot ignition will have a red or black ignitor

button (refer to Figure 2.4).

• An Intellifi re ignition system will not have a button.

Figure 2.4 Ignitor Button

RED OR BLACK IGNITOR BUTTON

Figure 2.3 Control Module

NG/LP SETTING

STATUS INDICATOR LED

SELECTOR

SWITCH

FLAME HI/LO SWITCH

5.

Module Reset
This module may lock-out under certain conditions.

When this occurs, the appliance will not ignite or

respond to commands. The module will go into lock-out

mode by emitting three audible beeps, then continuously

displaying a RED/GREEN error code at its status

indicator LED.

• Check battery tray. Remove batteries if installed.

Batteries should only be installed for use during power

outages. See Section G.

• Locate the module selector switch. (See Figure 2.3).
• Set the module selector switch to the OFF position.
• Wait fi ve (5) minutes to allow possible accumulated gas

to clear.

• Set the module selector switch to ON or REMOTE

position.

• Start the appliance.
WARNING! Risk of Explosion! DO NOT press the mod-

ule reset switch more than one time within a fi ve minute

time period. Gas may accumulate in fi rebox. Call a quali-

fi ed service technician.

4. If you intend to use both an optional wired wall switch

and the RC300 remote control to operate your fi replace,

the wall switch will override any commands given by

the remote.

Nine Hour Safety Shutdown Feature

This appliance will automatically shut down after nine

hours of continuous operation.

NOTICE: If the appliance shuts down after 9 hours of

continuous operation, the module must be reset. See

Module Reset instructions in this section.