Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11

Figure 3.1 Standing Pilot Flame Patterns

Burner Ignition and Operation

Frequency: Annually
By: Service Technician
Tools needed: Protective gloves, vacuum cleaner, whisk

broom, fl ashlight, voltmeter, indexed drill bit set, and a

manometer.
• Verify burner is properly secured and aligned with pilot

or igniter.

• Clean off burner top, inspect for plugged ports, corrosion

or deterioration. Replace burner if necessary.

• Replace Glowing embers with new dime-size pieces.

DO NOT block ports or obstruct lighting paths. Refer to

Section 12 for proper ember placement.

• Verify batteries have been removed from battery back-up

IPI systems to prevent premature battery failure or

leaking. For optimal battery life, locate the battery

pack outside of the control cavity on the hearth. This

placement will reduce the chances of overheating the

batteries during extended burns which could result in

reduced battery life or degradation.

• Check for smooth lighting and ignition carryover to all

ports. Verify that there is no ignition delay.

• Inspect for lifting or other fl ame problems.
• Verify air shutter setting is correct. See Section 12 for

required air shutter setting. Verify air shutter is clear of

dust and debris.

• Inspect orifi ce for soot, dirt and corrosion. Verify orifi ce

size is correct. See Service Parts List for proper orifi ce

sizing.

• Verify manifold and inlet pressures. Adjust regulator as

required.

• Inspect pilot fl ame pattern and strength. See Figure 3.1

and 3.2 for proper pilot fl ame pattern. Clean or replace

orifi ce spud as necessary.

• Inspect thermocouple/thermopile or IPI fl ame sensing rod

for soot, corrosion and deterioration. Clean with emery

cloth or replace as required.

• Verify thermocouple/thermopile millivolt output. Replace

pilot as necessary.

(Standing pilot only)

• Verify that there is not a short in fl ame sense circuit by

checking continuity between pilot hood and fl ame sense

rod. Replace pilot as necessary.

(IPI only)

Figure 3.2 IPI Pilot Flame Patterns