Codabar, Codabar start / stop characters, Codabar check character – Hand Held Products 5620 User Manual
Page 81: Codabar -3
![background image](/manuals/96438/81/background.png)
IMAGETEAM™ 2020/5620 System Manual
6 - 3
Codabar
Codabar
Codabar Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the bar code. You
may either transmit, or not transmit Start/Stop characters.
Default = Don’t Transmit.
Codabar Check Character
Codabar check characters are created using different “modulos.” You can
program the scanner to read only Codabar bar codes with Modulo 16 check
characters.
Default = No Check Character.
No Check Character indicates that the scanner reads and transmits bar code
data with or without a check character.
When Check Character is set to
Validate and Transmit, the scanner will only
read Codabar bar codes printed with a check character, and will transmit this
character at the end of the scanned data.
* On
Off
Transmit
* Don’t Transmit