Page 58: Manual/serial trigger, low power -4
3 - 4
IMAGETEAM™ 2020/5620 System Manual
Scanner Trigger Modes
Manual/Serial Trigger, Low Power
You can activate the scanner either by pressing the trigger, or using a serial
trigger command (see
trigger mode, the scanner scans until a bar code is read, or until the trigger is
released.
When in serial mode, the scanner scans until a bar code has been read or until
the deactivate command is sent. In serial mode, the scanner can also be set to
turn itself off after a specified time has elapsed (see
, which follows).
Read Time-Out (Serial Trigger Mode)
Use this selection to set a time-out (in milliseconds) of the scanner’s trigger when
using serial commands to trigger the scanner. Once the scanner has timed out,
you can activate the scanner either by pressing the trigger or using a serial
trigger command. After scanning the Read Time-Out bar code, set the time-out
duration (from 0-300,000 milliseconds) by scanning digits on the
inside the back cover, then scanning Save.
Default = 0 ms (no time-out).
Scanner Power Time-Out Timer
Note: The Scanner Power Time-out Timer option only applies to Manual/Serial
Trigger.
When there is no activity within a specified time period, the scanner enters low
power mode. Scan the Scanner Power Time-Out bar code to change the time-
out duration (in seconds). Then scan the digit value of the duration (from 1-
10,800 seconds) and the Save bar codes on the
back cover of this manual.
Default = 3600 seconds (1 hour).
* Manual/Serial Trigger
Read Time-Out