beautypg.com

Fuse, 58 servicing your generator – HONDA EM6500is User Manual

Page 60

background image

58

SERVICING YOUR GENERATOR

FUSE

Specified fuse:

FUSE HOLDER

FUSE (15A)

FUSE HOLDER COVER

FUSE (1A)

MAINTENANCE
COVER

COVER
SCREW

In the event of fuse failure, locate the cause of failure and repair before
you continue operation. If the fuse continues to fail, discontinue
generator use and consult an authorized Honda generator dealer.

If the fuse is blown, the starter motor won’t operate.

Turn the engine switch OFF and remove the key before checking or
replacing the fuse.

Loosen the cover screw and
remove the battery
maintenance cover.

1 A, 15 A

Never use a fuse with
different rating from that
specified. Serious damage to
the electrical system or fire
may result.

Replace the fuse with a
fuse of the same type and
rating.

Remove the fuse holder cover
and pull the fuse out.

Install the fuse holder cover and the maintenance cover in the
reverse order of removal (see page

).

Never operate the generator without the maintenance cover in place,
as poor engine and generator performance will result.

1.

2.

3.

4.

5.

56

07/03/13 16:29:24 31Z11600_059