Hearth and Home Technologies 8000CF-OAK-IPI User Manual
Page 51
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08
51
M. Air Shutter Setting
Air shutter settings should be adjusted by a qualifi ed ser-
vice technician at the time of installation. The air shutter is
set at the factory for minimum vertical vent run. Adjust air
shutter for longer vertical runs. See Figure 14.6.
• Loosen the wing nut.
• Push the air handle in to close the air shutter.
• Pull the air handle out to open the air shutter.
• Tighten the wing nut.
NOTICE: If sooting occurs, provide more air by opening
the air shutter.
Figure 14.6 Air Shutter
Figure 14.5 Fixed Glass Assembly
I. Fixed
Glass
Assembly
WARNING! Risk of Asphyxiation! Handle fi xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
• DO NOT strike, slam or scratch glass.
• DO NOT operate fi replace with glass removed, cracked,
broken or scratched.
• Replace as a complete assembly.
Removing Fixed Glass Assembly
• Pull the four glass assembly latches out of the groove on
the glass frame. Remove glass door from the appliance
(see Figure 14.5).
Replacing Fixed Glass Assembly
• Replace the glass door on the appliance. Pull out and
latch the four glass assembly latches into the groove on
the glass frame.
J. Install the Mesh
The screen mesh is built into front.
Air Shutter Settings
L. Install Trim and/or Surround
• Install optional trim kits and/or surrounds using the
instructions included with the accessory.
• Use non-combustible materials to cover the gap between
the sheet rock and the appliance (when applicable to the
model).
AIR SHUTTER
WING NUT
NG
LP
Burner
3/8 in.
Fixed
GLASS
ASSEMBLY
LATCHES
(BOTH BOTTOM
AND TOP)
K. Hood
Hood is included with the front and required in all
installations.
Note: The adjustable air shutter is not offered with the LP
model. The LP is fi xed, full open, for maximum primary air.