Framing and Clearances
A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traffi c and away from furniture and draperies.
NOTICE: Illustrations refl ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 5.1 Appliance Locations
A
G
F
A
E
D
MINIMUM
E
E
C
H
B
A
B
C
D
E
F
G
H
Inches
55-7/8
1/2
79
1
49
38-7/8
22
19-3/4
Millimeters
1419
13
2007
25
1219
987
559