J. install horizontal termination cap – Hearth and Home Technologies 8000CF-OAK-IPI User Manual

Page 41

background image

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08

41

Figure 10.25 Venting through the wall

INTERIOR

HEAT SHIELD OR

EXTENDED

HEAT SHIELD

WALL SHIELD

FIRESTOP

HEAT SHIELD

1-1/2 IN. (38 MM) MIN.

OVERLAP

SHEATHING

VENT DEPTH FROM BACK OF APPLIANCE TO

OUTSIDE SURFACE OF EXTERIOR WALL

(SEE CHART BELOW)

SLIP SECTION

CAN BE EXTENDED

INNER VENT

OUTER VENT

EXTERIOR

Note: When using termination caps with factory-supplied
heat shield attached, no additional wall shield fi restop is
required on the exterior side of a combustible wall.

J. Install Horizontal Termination Cap

WARNING! Risk of Fire! The telescoping fl ue section of
the termination cap MUST be used when connecting vent.

• 1-1/2 (38 mm) minimum overlap of fl ue telescoping

section is required.

Failure to maintain overlap may cause overheating and
fi re.

• Vent termination must not be recessed in the wall. Siding

may be brought to the edge of the cap base.

• Flash and seal as appropriate for siding material at

outside edges of cap.

• When installing a horizontal termination cap, follow

the cap location guidelines as prescribed by current
ANSI Z223.1 and CAN/CGA-B149 installation codes
and refer to Section 6 of this manual.

CAUTION! Risk of Burns! Local codes may require in-
stallation of a cap shield to prevent anything or anyone
from touching the hot cap.

Cap Specifi cation Chart

(depth without using additional pipe sections)

8000

Series

DVP-TRAPK1

Top Vent

Depth

DVP-TRAP1

Rear Vent

Depth

DVP-TRAPK2

Top Vent

Depth

DVP-TRAP2

Rear Vent

Depth

4-1/8 in. to

6 in.

N/A

6-5/8 in. to

10-5/8 in.

N/A

DVP-HPC1

Top Vent

Depth

DVP-HPC1

Rear Vent

Depth

DVP-HPC2

Top Vent

Depth

DVP-HPC2

Rear Vent

Depth

4-1/8 in. to

6-1/4 in.

N/A

6-1/8 in. to

10-1/4 in.

N/A

DVP-TRAP1 can adjust 1-7/8 in. (4-3/16 to 6-1/16)

DVP-TRAP2 can adjust 4 in. (6-9/16 to 10-9/16)

DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8)

DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2)