beautypg.com

Hoshizaki MODULAR CRESCENT CUBER KM-630MRH User Manual

Page 52

background image

52

IMPORTANT

Always install a new Drier every time the sealed refrigeration system is
opened. Do not replace the Drier until after all other repair or replacement
has been made.

1) Turn off the power supply.

2) Remove the panels.

3) Recover the refrigerant and store it in an approved container.

4) Remove the screw and the Solenoid.

5) Disconnect the Hot Gas Valve or Line Valve using brazing equipment.

6) Install the new valve.

WARNING

Always protect the valve body by using a damp cloth to prevent the valve
from overheating. Do not braze with the valve body exceeding 250°F.

7) Install the new Drier.

8) Check for leaks using nitrogen gas (140 PSIG) and soap bubbles.

9) Evacuate the system, and charge it with refrigerant. For air-cooled and water-
cooled models, see the Nameplate for the required refrigerant charge. For remote
air-cooled models, see the Charge Label in the machine compartment.

10) Cut the leads of the Solenoid allowing enough lead length to reconnect using
closed end connectors.

11) Connect the new Solenoid leads.

12) Attach the Solenoid to the valve body, and secure it with a screw.

13) Replace the panels in their correct positions.

14) Turn on the power supply.

This manual is related to the following products: