Performance data, A] km-630mah – Hoshizaki MODULAR CRESCENT CUBER KM-630MRH User Manual
Page 37
37
4. PERFORMANCE DATA
[a] KM-630MAH
Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for
reference only.
We reserve the right to make changes in specifications and design without prior notice.
70/21
600
272
562
255
514
233
80/27
571
259
512
232
466
211
90/32
562
255
470
213
422
191
lbs./day kg./day
100/38
554
251
459
208
378
171
70/21
80/27
90/32
watts
100/38
70/21
341
1.29
287
1.09
253
0.96
80/27
300
1.14
216
0.82
204
0.77
90/32
287
1.09
157
0.59
135
0.51
gal./day m
3
/day
100/38
223
0.84
152
0.57
115
0.43
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
245
17.2
267
18.8
296
20.8
80/27
262
18.4
296
20.8
324
22.7
90/32
267
18.8
320
22.5
349
24.5
PSIG kg/cm
2
G
100/38
272
19.1
327
23.0
375
26.4
70/21
43
3.0
44
3.1
46
3.2
80/27
44
3.1
46
3.2
47
3.3
90/32
44
3.1
47
3.3
49
3.4
PSIG kg/cm
2
G
100/38
44
3.1
47
3.3
50
3.5
3.5
2.9
TOTAL HEAT OF REJECTION FROM CONDENSER
9639 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
3.8
41
34
35
40
2.2
2.0
1297
1323
1352
1370
38
41
44
48
1275
1274
1305
1332
1336
1250
1268
1274
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
90/32
31
33
34
37
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
2.4
4.4
3.1
3.8
3.0
2.4
4.0