[b2] KM-630MWH Serial #M20301E -
Note: Pressure data is recorded at 5 minutes into freeze cycle. The data without * should be used for
reference only.
We reserve the right to make changes in specifications and design without prior notice.
70/21
*621
282
603
273
563
256
80/27
607
275
578
262
532
241
90/32
603
273
*558
253
514
233
lbs./day kg./day
100/38
590
268
548
248
*473
215
70/21
80/27
90/32
watts
100/38
70/21
*653
2.47
664
2.51
814
3.08
80/27
661
2.50
720
2.73
903
3.42
90/32
664
2.51
*691
2.62
887
3.36
gal./day m
3
/day
100/38
739
2.80
737
2.79
*1068
4.04
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
*280
19.7
280
19.7
286
20.1
80/27
280
19.7
280
19.7
288
20.2
90/32
280
19.7
*280
19.7
288
20.2
PSIG kg/cm
2
G
100/38
282
19.9
285
20.0
295
20.7
70/21
*47
3.3
47
3.3
48
3.4
80/27
47
3.3
48
3.4
49
3.4
90/32
47
3.3
*48
3.4
49
3.4
PSIG kg/cm
2
G
100/38
48
3.3
48
3.4
*50
3.5
WATER FLOW FOR CONDENSER
39 gal. / h (AT 100ºF (38ºC) / WT 90ºF (32ºC))
PRESSURE DROP OF COOLING WATER LINE
less than 10 PSIG
TOTAL HEAT OF REJECTION FROM COMPRESSOR
1894 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
*41
3.5
3.4
3.4
3.1
2.7
2.1
*2.0
3.4
2.8
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
36
32
33
HARVEST CYCLE TIME
HEAD PRESSURE
2.3
8770 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
38
*2.3
1275
1278
1282
*1285
1271
1271
1275
*1279
1280
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
35
37
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
90/32
*1268
1270
1271
*35
*3.8
*31
32
32
34