beautypg.com

Warning, Maintaining and servicing the appliance – Heat & Glo Fireplace 6100PLUS User Manual

Page 29

background image

Hearth & Home Technologies • 6100PLUS • 4041-127 Rev D • 09/05

29

Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualifi ed
service technician should perform an appliance check-up at the beginning of each heating season.

Fire Risk
Explosion Risk

Inspect external vent cap regularly.
• Ensure no debris blocks cap.

Combustible materials blocking cap may
ignite.

• Restricted air flow affects burner

operation.

WARNING

Annual inspection by qualified technician
recommended.
Check:
• Condition of doors, surrounds and fronts.
• Condition of glass, glass assembly and glass

seal.

• Obstructions of combustion and ventilation

air.

• Condition of logs.
• Condition

of

rebox.

• Burner ignition and operation.
• Burner air shutter adjustment.
• Gas connections and fi ttings.
• Obstructions of termination cap.
Clean:
• Glass.
• A i r p a s s a g e w a y s , g r i l l e s , c o n t r o l

compartment.

• Burner, burner ports.
Risk of:
Fire
• Delayed ignition or explosion
• Exposure to combustion fumes
• Odors

WARNING

13

Maintaining and Servicing the Appliance

Risk of injury or property damage

Before servicing:
• Turn off gas.
• Turn off electricity to appliance.
• Disable remote control, if one is present.
• Ensure appliance is completely cooled.
After Servicing:
• Replace any screen or barrier that was removed.
• Reseal and reinstall any venting removed for

servicing.

WARNING

C. HRV200PLUS

Please refer to the HRV200PLUS manual for additional
maintenance requirements for the ventilation portion of the
6100PLUS.

A. Annual Maintenance

To ensure that your gas appliance operates in a safe and
effi cient manner, it needs to be inspected at least on an an-
nual basis by a qualifi ed fi eld service person. Like any gas
appliance, This gas appliance must be tuned up to ensure
optimum performance.

B. Cleaning the Burner and Control Compartment

Keep the burner and control compartment clean by brushing
and vacuuming at least once a year. Always turn the wall (or
dashboard switch) and the gas valve off before cleaning.

D. Ember Bed Bulb Replacement

• Remove two screws from dash plate holding each

bulb bracket.

• Pull socket down and forward to access bulb, replace the

bulb and return to installed position. See Figure 13.1.

Note: After extended periods of burning, fi lm may build up
on the fl ame sensor. The fl ame sensor should be cleaned
annually with emery cloth to remove this build up.

Figure 13.1 Bulb Replacement