beautypg.com

C. system wiring – Heat & Glo Fireplace 6100PLUS User Manual

Page 15

background image

Hearth & Home Technologies • 6100PLUS • 4041-127 Rev D • 09/05

15

C. System Wiring

Note:

The 6100PLUS must be electrically wired and grounded in accordance with local codes or, in the absence

of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code,
CSA C22.1.

Figure 8.1

Intermittent Pilot Ignition Wiring Diagram

6100PLUS Requirements

• This gas appliance requires a 110VAC supply to the gas appliance junction box for operation. A wiring diagram is shown

in Figure 8.1.

• The 6100PLUS is equipped with an intermittent pilot control valve which operates on a 3 volt system. See ignition wiring

diagram, Figure 8.1.

• The 6100PLUS is supplied with a 3 volt AC transformer, which requires the installation of the supplied junction box. It is

highly recommended that the junction box be installed at this time to avoid future reconstruction.

Note: Wire terminal latch can become
damaged if excessive force is used
when releasing wire. Please use caution
in pressing retainer.