beautypg.com

F. junction box installation – Heat & Glo Fireplace 6100PLUS User Manual

Page 19

background image

Hearth & Home Technologies • 6100PLUS • 4041-127 Rev D • 09/05

19

Figure 8.6

Junction Box

WHT

WHT

BLK

BLK

GRN wire
inside box

Copper
ground attached
to GRN screw with
GRN wire

14/2WG

Cover Plate
outside firebox

Romex
Connector

Figure 8.5

Junction Box Detail

F. Junction Box Installation

If the box is being wired from the OUTSIDE of the appliance:

• Remove the cover plate located on the outer shell - right side (see Figure 8.5).
• Install the supplied Romex™ connector in the cover plate.
• Feed the necessary length of wire through the connector.
• Make all necessary wire connections and reattach the cover plate to the outer shell.

If the box is being wired from the INSIDE of the appliance:

• Remove the screw attaching the junction box/receptacle to the outer shell, rotate the junction box inward to disengage

it from the outer shell (see Figure 8.5).

• Pull the electrical wires from outside the appliance through this opening into the valve compartment.
• Feed the necessary length of wire through the connector.