beautypg.com

Finishing, Warning, A. mantel projections – Heat & Glo Fireplace 6100PLUS User Manual

Page 20: B. facing material

background image

20

Hearth & Home Technologies • 6100PLUS • 4041-127 Rev D • 09/05

A. Mantel Projections

Figure 9.1 shows the minimum vertical and corresponding
maximum horizontal dimensions of appliance mantels or
other combustible projections above the top front edge of
the appliance.

B. Facing Material

1 in. (25 mm) min.
to perpendicular wall

A

3-1/2 in. (89 mm) min.
from fireplace opening
to perpendicular wall

B

48 in.

(1219 mm)

max.

Mantel Leg or

Perpendicular Wall

Top of
Appliance

Drywall

A

B

Figure 9.2

Mantel Leg or Wall Projections

(Acceptable on both sides of opening)

High
Temperature
Sealant

These surfaces
may be covered with
noncombustible material.

These surfaces
may be covered with
noncombustible
material.

Figure 9.3

Noncombustible Facing Diagram

9

Finishing

Fire Risk

Finish all edges and fronts to clearances and
specifi cations listed in manual.

WARNING

• Metal appliance front may be covered with non-

combustible material only.

Do NOT overlap combustible materials onto appliance
front.

• Install combustible materials only up to specifi ed

clearances on top, front and sides.

• Seal joints between the fi nished wall and appliance

top and sides using only a 300° F minimum sealant.

Fire Risk
Explosion Risk
• Facing

and/or

fi nishing materials must never

overhang into the glass opening.

• Overhanging materials may ignite.

May interfere with proper operation of glass
assembly.

WARNING

Measured from top of fireplace opening (in inches)

3

4

5

6

7

8

9

10

11

12

10-3/4

13-3/4

13-3/4

13-3/4

16-3/4

16-3/4

16-3/4

19-3/4

19-3/4

19-3/4

32-7/8 in. minimum

to ceiling

Figure 9.1

Clearances to Mantels or Other Combustibles Above

Appliance

Fire Risk

Do NOT obstruct air inlets.
Finishing materials must not interfere with:
• Air fl ow through inlets.
• Access for service.

WARNING