beautypg.com

Warning – Heat & Glo Fireplace 6100PLUS User Manual

Page 13

background image

Hearth & Home Technologies • 6100PLUS • 4041-127 Rev D • 09/05

13

A small amount of air will be in the gas supply lines. When
fi rst lighting appliance it will take a short time for air to
purge from lines. When purging is complete the appliance
will light and operate normally.

WARNING

Fire Risk
Explosion Risk
• Gas build-up during line purge may

ignite.

• Purge should be performed by qualifi ed

technician.

• Ensure adequate ventilation.

Ensure there are no ignition sources such
as sparks or open fl ames.

WARNING

Fire Risk

Do NOT change the valve settings.
• This valve has been preset at the

factory.

Changing valve settings may result in fi re
hazard or bodily injury.

WARNING

CHECK FOR GAS LEAKS

Fire Risk
Explosion Risk
Asphyxiation Risk
• Check all fi ttings and connections.
• Do not use open fl ame.

After the gas line installation is complete,
all connections must be tightened and
checked for leaks with a commercially
available, non-corrosive leak check
solution. Be sure to rinse off all leak check
solution following testing.

Fittings and connections may have loosened
during shipping and handling.

D. High Altitude Installations

The 6100PLUS is power vented. High altitude gas appliance
considerations are no longer of concern, as long as the gas
appliance is properly installed with the HRV200PLUS prop-
erly balanced (refer to HRV200PLUS manual).