background image

altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).

Non-operating

-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).

Relative Humidity

Relative Humidity

Relative Humidity

Relative Humidity
(non-condensing)

Operating

10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.

Non-operating

5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.

Altitude

Altitude

Altitude

Altitude

Operating

3048 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).

Non-operating

9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).

Acoustic Noise

Acoustic Noise

Acoustic Noise

Acoustic Noise

Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).

Idle

Idle

Idle

Idle

L WAd

5.6 B for 1P Non-Redundant; 5.5 B for 2P
Redundant

L pAm

39 dB for 1P Non-Redundant; 39 dB for 2P
Redundant

Operating

Operating

Operating

Operating

L WAd

5.6 B for 1P Non-Redundant; 5.5 B for 2P
Redundant

L pAm

39 dB for 1P Non-Redundant; 39 dB for 2P
Redundant

NOTE:

NOTE:

NOTE:

NOTE: The Listed sound levels apply to standard shipping configurations.
Additional options may result in increased sound levels.

Emissions Classification

Emissions Classification

Emissions Classification

Emissions Classification
(EMC)

FCC Rating

Class B

Normative Standards

CISPR 22; EN55022; EN55024; FCC CFR 47,
Pt 15; ICES-003; CNS13438; GB9254;
K22;K24; EN 61000-3-2; EN 61000-3-3; EN
60950-1; IEC 60950-1

QuickSpecs

HP ProLiant DL370 Generation 6 (G6)

HP ProLiant DL370 Generation 6 (G6)

HP ProLiant DL370 Generation 6 (G6)

HP ProLiant DL370 Generation 6 (G6)

HP ProLiant ML370 Generation 6 (G6)

HP ProLiant ML370 Generation 6 (G6)

HP ProLiant ML370 Generation 6 (G6)

HP ProLiant ML370 Generation 6 (G6)

Technical Specifications

DA - 13242 Worldwide — Version 3 — April 2, 2009

Page 54