beautypg.com

Quickspecs – HP ProLiant DL370 User Manual

Page 21

background image

NOTE:

NOTE:

NOTE:

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are
ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on CTO
product offerings and requirements.
NOTE:

NOTE:

NOTE:

NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start
with a CTO Chassis.
NOTE:

NOTE:

NOTE:

NOTE: FIO indicates that this option only available as a Factory Installable Option.

Step 1: Base Configuration (choose one of the following configurable models)

Step 1: Base Configuration (choose one of the following configurable models)

Step 1: Base Configuration (choose one of the following configurable models)

Step 1: Base Configuration (choose one of the following configurable models)

Models

Models

Models

Models

HP ProLiant ML370 G6 Tower Models

HP ProLiant ML370 G6 Tower Models

HP ProLiant ML370 G6 Tower Models

HP ProLiant ML370 G6 Tower Models

HP ProLiant ML370 G6 SFF CTO Chassis

483880-B21

NOTE:

NOTE:

NOTE:

NOTE: Supports Small Form Factor (SFF) - 2.5" Drives

Factory Integrated Model ships with:

Factory Integrated Model ships with:

Factory Integrated Model ships with:

Factory Integrated Model ships with:

HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter
Integrated Lights-Out embedded
HP Smart Array P410i/Zero Memory Controller
(8) Hot-Plug (SFF) SAS/SATA Drive Bays
(9) available PCI-e Gen2 slots
(5) USB ports
(3) Hot Plug Fans
Tower Form Factor

HP ProLiant ML370 G6 LFF CTO Chassis

483879-B21

NOTE:

NOTE:

NOTE:

NOTE: Supports Large Form Factor (LFF) - 3.5" Drives

Factory Integrated Model ships with:

Factory Integrated Model ships with:

Factory Integrated Model ships with:

Factory Integrated Model ships with:

HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter
Integrated Lights-Out embedded
HP Smart Array P410i/Zero Memory Controller
(6) Hot-Plug (LFF) SAS/SATA Drive Bays
(9) available PCI-e Gen2 slots
(5) USB ports
(3) Hot Plug Fans
Tower Form Factor

HP ProLiant DL370 G6 Rack Models

HP ProLiant DL370 G6 Rack Models

HP ProLiant DL370 G6 Rack Models

HP ProLiant DL370 G6 Rack Models

HP ProLiant DL370 G6 SFF CTO Chassis

483874-B21

NOTE:

NOTE:

NOTE:

NOTE: Supports Small Form Factor (SFF) - 2.5" Drives

Factory Integrated Model ships with:

Factory Integrated Model ships with:

Factory Integrated Model ships with:

Factory Integrated Model ships with:

HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter
Integrated Lights-Out embedded
HP Smart Array P410i/Zero Memory Controller
(8) Hot-Plug (SFF) SAS/SATA Drive Bays
(9) available PCI-e Gen2 slots
(5) USB ports
(3) Hot Plug Fans
4U Rack Form Factor

HP ProLiant DL370 G6 LFF CTO Chassis

483873-B21

NOTE:

NOTE:

NOTE:

NOTE: Supports Large Form Factor (LFF) - 3.5" Drives

Factory Integrated Model ships with:

Factory Integrated Model ships with:

Factory Integrated Model ships with:

Factory Integrated Model ships with:

HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter

QuickSpecs

HP ProLiant DL370 Generation 6 (G6)

HP ProLiant DL370 Generation 6 (G6)

HP ProLiant DL370 Generation 6 (G6)

HP ProLiant DL370 Generation 6 (G6)

HP ProLiant ML370 Generation 6 (G6)

HP ProLiant ML370 Generation 6 (G6)

HP ProLiant ML370 Generation 6 (G6)

HP ProLiant ML370 Generation 6 (G6)

Configuration Information - Factory Integrated Models

DA - 13242 Worldwide — Version 3 — April 2, 2009

Page 21