3

595-5497-12

SPECIFICATIONS

Range . . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.

(30.5 m) with Range Boost.
[varies with surrounding
temperature]

Sensing Angle . . . . . . . Up to 240°
Electrical Load . . . . . . . Up to 500 Watt Maximum

Incandescent

Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . . 1, 5, 20 minutes
Replacement lamp . . . . T 500W (or less) halogen 120

VAC

D

ual

B

rite

®

Timer . . . . . 3, 6 hours, Dusk-to-Dawn

HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.

Motion

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1

1

/

2

minute warm up period be-

fore it will detect motion. When first turned on
or when switching modes wait 1

1

/

2

minutes.

Bottom of Sensor

Avoid aiming the sensor at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where

pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

Maximum Range

Maximum

Coverage Angle

8 ft.

(2.4 m)

70 ft.

100 ft.

(21 m) (30.5 m)

Boosted

Least Sensitive

Most Sensitive

Sensor

The detector is less sensitive to motion directly towards it.

240°

B

O

O

S

T

MAX

MIN

RANGE

ON - TIME DUAL BRITE

TEST 1 5 2 0

MINUTES

OFF 3 6 DUSK TO

HOUR DAWN

Turn the RANGE control to the mid position,

D

ual

B

rite

®

to OFF and the ON-TIME control to the

TEST position.

Loosen the clamp screw in the

sensor ball joint and gently
rotate the sensor.

Walk through the coverage

area noting where you are
when the lights turn on. Move
the sensor head up, down,
or sideways to change the
coverage area.

Adjust the RANGE as needed.

RANGE set too high may
increase false triggering.

Secure the sensor head’s
aim by tightening the clamp
screw.
Do not overtighten the
screw.

Set the amount of TIME you

want the lights to stay on after
motion is detected (1, 5, or 20 minutes).

Set the D

ual

B

rite

®

switch to the amount of time

after dusk you want the lights on at low level (Off,
3, 6 Hrs., Dusk-to-Dawn).

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Motion