Table 1-3. Supplemental Characteristics (continued)
Outputs
40 W Low
40 W High
80 W Low
80 W High
Voltage
Voltage
Voltage
Voltage
Programming Resolution:
Voltage
6 mV
15 mV
6 mV
15 mV
+Current
25 mA
10 mA
50 mA
20 mA
OVP
100 mV
250 mV
100 mV
250 mV
Readback Resolution:
Voltage
6 mV
15 mV
6 mV
15 mV
+ or-Current
2 mA
0.8 mA
4 mA
1.6 mA
Fixed Overvoltage Protection: (Measure at output terminals +V and -V):
Minimum
22.5 V
56 V
22.5 V
56 V
Nominal
24 V
60 V
24 V
60 V
Maximum
26 V
64 V
26 V
64 V
AC Input Power and Current:
Maximum Power = 550 W
100 V Option
120 V Option
220 V Option
240 V Option
High Line Inrush Current
(pk)
85 A
85 A
50 A
50 A
High Line Input Current
(rms)
6.3 A
5.7 A
3.0 A
3.0 A
Fuse Rating
8 A
8 A
4 A
4 A
HP-IB Interface Capabilities:
SH1, AH1, T6, L4, SR1, RL1, PP1, DC1, DT0, C0, E1
Current Sink Capability:
Current sink limits are fixed approximately 10% higher than the maximum current source limits for a given operating
voltage at any voltage above 2.5 V (see Chapter 4).
Command Processing Time: (see Figure 1-3):
7 milliseconds typical (with front panel display disabled). Using STO and RCL commands allows you to change all the
voltage and current settings in about 10 mS (with front panel display disabled).
Series and Parallel Operation:
Two outputs can be operated directly in parallel or can be connected for straight series operation. Refer to Chapter 4 for
more information.
Reactive Load Capability:
All outputs have been designed with the ability to operate with significant reactive loads without instability (refer to
Figures 1-4 through 1-6).