6. ELECTRICAL CONNECTION

6. ELECTRICAL CONNECTION

6. ELECTRICAL CONNECTION

6. ELECTRICAL CONNECTION

6. ELECTRICAL CONNECTION

WARNING

WARNING

WARNING

WARNING

WARNING

1. Electrical connection must be made in accordance with the instructions on

a “WARNING” tag, provided with the pig tail leads in the Junction Box.

2. This icemaker requires a ground that meets the national and local electrical

code requirements. To prevent possible electrical shock to individuals or
extensive damage to the equipment, install a proper ground wire to the
icemaker.

• On three phase models, the Voltage Tap Switch in the unit should be positioned to match

incoming voltage at start-up. See Fig. 6.

• This icemaker must have a separate power supply or receptacle of proper capacity. See

the Nameplate.

• The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.

• When excessive voltage is supplied to the Controller Board, the icemaker stops running

in 3 seconds. See “10. START UP.”

• Usually an electrical permit and services of a licensed electrician are required.