NAILER

QUICK

CONNECTOR

QUICK

COUPLER

AIR

HOSE

QUICK

COUPLER

QUICK

CONNECTOR

OILER

REGULATOR

FILTER

AIR

COMPRESSOR

CONNECTION TO AIR SUPPLY

TESTING THE FULL SEQUENTIAL SAFETY TRIP MECHANISM

WARNING: Even though the Nailer should be empty during this procedure,

ALWAYS point the Nailer at a piece of scrap wood when testing.

1.

Make sure the tool is disconnected from its air supply.

2.

Completely empty the Magazine (85) of Nails. Then, close the Magazine.

(See Figure B.)

SKU 93257 For technical questions, please call 1-800-444-3353 PAGE 6

TRIGGER

(60)

MAGAZINE

(85)

SAFETY

(38)

FIGURE A

FIGURE B

AIR PLUG

(82-not included)

OPERATION

For best service, you should incorporate an oiler, regulator, and inline filter, as

shown in the diagram below. Hoses, couplers, oilers, regulators, and filters are

all available at Harbor Freight Tools. NOTE: If an automatic oiler is not used,

for smoother operation and to extend the life-span of the tool, put 3-5 drops of

pneumatic Tool Oil (93) in the attached Air Plug (82-not included) before each

use.