CONVERTING TO LP GAS

or Converting Back to Natural Gas from LP

CONVERT THE PRESSURE REGULATOR

1. Locate the pressure regulator in the range.

2. Follow the directions in box

or

that

match your regulator type.

B

A

WARNING: Do not remove the pressure
regulator from the range.

2

CONVERT THE PRESSURE REGULATOR FOR

ELECTRIC IGNITION MODELS

1. Unscrew the cap from the pressure regulator.
Be sure the spring stays in place.
2. Turn the cap toward the desired setting.
3. Replace the cap of the regulator. The letters
corresponding with the type of gas being used
should be visible on the exposed end of the cap.

A

HOW TO CONVERT A STANDARD TWIN
BURNER RANGE FOR USE WITH LP GAS OR
NATURAL GAS

This range was adjusted for Natural or LP gas as
specified on the serial plate.
The conversion should be done by a qualified
technician or installer.
For gas conversion you will need a 1/2

² open

end wrench.

PREPARE RANGE FOR CONVERSION

(1)

Turn off gas supply at the wall.

(2) Turn off the electrical power to the range.
If range has not yet been connected to gas supply,
or if flexible connection was made, range may be
pulled out from the wall to make conversion easier.

1

Pressure regulator location
under the cooktop

Hollow end

towards

regulator for
Natural gas.

Cap

Spring

On

Shut-off
switch for
oven only

Solid end
towards
regulator for
LP gas

(continued next page)

Off