GAS CONNECTION FOR ELECTRIC IGINITION

MODELS

GAS CONNECTION FOR STANDING PILOT MODELS

GAS PIPE AND ELECTRIC OUTLET LOCATIONS

PREPARATION

• Remove all tape and packaging. Lift up the
cooktop and remove any packing material under
it. Make sure the burners are properly seated
and level.
• Remove plastic film that covers some chrome
parts (around oven door, side trim).
• Take the accessory pack out of the oven.
• Check to be sure that no range parts have
come loose during shipping.

PROVIDE ADEQUATE GAS SUPPLY

Your range is designed to operate at a pressure
of 4

² of water column on natural gas or, if designed

for LP gas (propane or butane), 10

² of water

column. Make sure you are supplying your range
with the type of gas for which it is designed. This
range is convertible for use on natural or propane
gas, if you decide to use this range on a different
type of gas, conversion adjustments must be
made by a service technician or other qualified
person before attempting to operate the range on
that gas.
For proper operation, the maximum inlet
pressure to the regulator should be no more
than 14

² of water column pressure. The inlet

pressure to the regulator must be at least 1

²

greater than regulator manifold pressure.
Examples: If regulator is set for Natural gas 4

²

manifold pressure, inlet pressure must be at
least 5

²; if regulator has been converted for LP

gas 10

² manifold pressure, inlet pressure must

be at least 11.

²

The pressure regulator located at the inlet of the
range manifold

MUST remain in the supply line

regardless of whether natural or LP gas is being
used. A flexible metal appliance connector used
to connect the range to the gas supply line
should have an I.D. of 1/2

² or 3/4² and be 5 feet

in length for ease of installation. In Canada,
flexible connectors must be single wall metal
connectors no longer than 6 feet in length.
Seal any openings in the wall behind the range
and in the floor under the range after gas supply
line is installed.

1

Manual
shut-off

valve

Manual
shut-off

valve

Flare

union

Flare

union

Flare

union

Flexible

appliance

conduit

Service shut-

off valve

ON

ON

OFF

OFF

OFF

Flare

union

Pressure
regulator

Pressure
regulator

Flexible

appliance

conduit

(continued next page)

22

²

19

²

23

²

7

²

2

²

10

1

/

2

²

11

1

/

2

²

7

²

CL

Recommended area

for 120V outlet on

rear of wall and area

for thru the wall

connection of pipe

stub and shut-off

valve is shaded area.

Recommended area for thru the floor

connection of pipe stub and shut-off valve

Centerline
of range

Wall edge

ON