beautypg.com

I. dispense mode switch – Hoshizaki DCM-300BAH(-OS) User Manual

Page 17

background image

17

Fig. 6

11) Disengage the safety switch. Move the control switch to the "OFF" position, then move

the power switch to the "OFF" position. Turn off the power supply.

12) Clean the storage bin liner, cover, and components using a neutral cleaner. Rinse

thoroughly after cleaning. Replace the storage bin cover in its correct position.
WARNING! CHOKING HAZARD: Ensure all components, fasteners, and
thumbscrews are securely in place. Make sure that none have fallen into the
storage bin.

13) Move the power switch to the "ON" position, then replace the front panel in its correct

position. Turn on the power supply, then move the control switch to the "ICE" position to
start the automatic icemaking process.

I. Dispense Mode Switch

The dispense mode switch has "CONTINUOUS" and "PORTION" positions.
When the dispense mode switch is in the "CONTINUOUS" position, ice dispenses
continuously for a maximum of 60 seconds per activation.
When the dispense mode switch is in the "PORTION" position, ice dispenses for the
amount of time determined by the ice dispense time setting. The ice dispense time
control is located on the control board. The dial indicates dispense time in seconds.
See Fig. 6. When shipped, the ice dispense time control is set to the minimum
dispense time of 0.6 sec. At this setting, approximately 0.72 oz. of ice is dispensed. The
DCM-300BAH(-OS) dispenses approximately 1.2 oz. of ice per second.